What are the methods for the electrical control transformation of electric scrapers?
Release time:
2023-03-31
It has been decades since the introduction of electric scrapers to become the main means of transportation in mines. Because of its high efficiency, reliability, and simple operation and maintenance, it is highly popular in underground mines.The electrical control transformation of the electric scraper has improved the performance and reliability of the electric scraper, and the production efficiency has been improved while also reducing maintenance costs.
It has been decades since the introduction of electric scrapers to become the main means of transportation in mines. Because of its high efficiency, reliability, and simple operation and maintenance, it is highly popular in underground mines.The electrical control transformation of the electric scraper has improved the performance and reliability of the electric scraper, and the production efficiency has been improved while also reducing maintenance costs.
1. Increase the working voltage of the main contactor coil from the original AC 24V to AC 380V. Through this improvement, the operating current of the contactor is reduced by about 16 times. The advantage of this change is to reduce the voltage loss of the control contact, so that the heat generated by the contactor control contact is greatly reduced, and the electrical corrosion of the contact is suppressed at the same time.
2. The original thermal protection relay was replaced by a comprehensive motor protector. The purpose of the replacement is as follows:
A. Provide more protection for the motor and provide a reliable working environment for the motor.
B. Since the motor integrated protector uses induction to detect current, the use of thermal relays to generate intermediate nodes is reduced. Due to the small contact capacity of the thermal relay, it is easy to damage the shortcomings, and because the motor power line is drawn directly from the contactor, the mechanical strength is also increased.
3. Intermediate relays are used. The regulations for underground mine mobile equipment stipulate that the operating voltage shall not be greater than AC 24V. Since the coil voltage of the main AC contactor in the first item is AC 380v, in order to make this circuit meet the requirements of the regulations, intermediate relays are used for high and low voltage isolation.
4. The operating power supply is changed to a DC switching power supply, which can make full use of the advantages of the wide input range of the switching power supply, and eliminate the malfunction caused by the large voltage drop at start-up due to the long distance of the scraper's power supply.
Recommended news
Mante Machinery
Contact person: Mr. Sui
Tel: 086-13863833991
Email: yantaimante@163.com
Add: No. 28 Chuangye Road, Gaoxin District, Yantai City, Shandong Province
Copyright © Mante Machinery
右侧在线客服组件
SAF Coolest v1.2 设置面板 SWHSX-ZXOZ-JXZVE-ZWS
无数据提示
Sorry, there is currently no content in the current column!
You can view other columns or return to HOME